You should pay attention to the following
aspects when installing the filter press:
1. There should be enough space for operation and maintenance around the filter press. The hydraulic pressure filter press should choose an appropriate position to place the hydraulic station to ensure that the hydraulic station can work normally.
2. Put the filter plates and arrange the feeding, washing and draining pipelines according to the working requirements. A filter pressure indicator and a return channel should be equipped to control the filter pressure. If it is a diaphragm squeeze type, a compressed air pipeline is necessary.
3. In the hydraulic filter press, clean 20#-40# hydraulic mechanical oil is injected into the oil tank of the hydraulic station, and the operating temperature is >-5℃; if the ambient temperature is low, hydraulic oil with similar viscosity and low freezing point can be selected. Hydraulic oil must pass 80-100 mesh filter to be put in.
4. The filter press should be installed on a level concrete foundation. The thrust plate foot at the feed end is fixed on the foundation with anchor bolts; the bracket end does not require anchor bolts, or the anchor bolts are positioned and locked with two nuts, and the nut pads leave a proper gap between the film and the machine leg, the machine leg can be slightly stretched. Before positioning, the installer should correct the verticality of the beam and the large plane of the thrust plate.
5. The mechanical or hydraulic pressing device should work correctly when the power is turned on and the starter motor is connected. The pressure gauge should rise steadily when the hydraulic pressure is pressed and pressurized, and the hydraulic system has no leakage phenomenon. Correctly adjust the working pressure of the hydraulic station according to the size of the model.If the fuel tank is found to have insufficient oil storage after the test machine, it must be replenished.
6. The foundation structure should be designed by the construction engineers according to the equipment load conditions, and the anchor bolts should be grouted twice with the reserved holes.
After the filter press has completed the above operations, there will be no problems with the installation of the filter press. As long as you pay attention to the maintenance and maintenance of the filter press in daily use, you can guarantee its working status and work efficiency.